2KV PV Wire

AL 2KV PV WIRE

AL 2KV PV WIRE

CONSTRUCTION PARAMETERS:

INSULATION: Flame retardant Cross-Linked Polyethylene (XLPE)

INSULATION COLOR: Black or Redx

 

PRODUCT FEATURES:

TEMPERATURE RATINGS: 90°C Dry, 90°C Wet. Rated for direct burial, moisture resistant, meets cold bend & cold impact test at -40°C

 

VOLTAGE RATING: 2,000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31 (A) and other applicable parts of the National Electrical Code (NEC), NFPA 70

 

STANDARDS & APPROVALS:

UL 44 Type RHH/RHW-2, 2000V, UV/Sunlight Resistant
UL 4703 Type PV
ASTM B800 , B801, B836
Flame Test: UL 1581 VW-1
RoHS, EPA 40 CFR, Part 26, Subpart C, heavy metals per Table 1, TLCP method

SPECIFICATIONS

KINGWIRE AL 2KV TYPE PV     Physical Characteristics

Conductor Size Stranding Conductor Nominal Diameter Insulation
Thickness
Nominal Outside
Diameter
AL Weight Nominal Net Weight Maximum Pulling Tension Minimum Bending Radius*
AWG/Kcmil Min. No. inch mils inch lb/1000ft lb/1000ft lb inch
4/0^ 18/w 0.475 105 0.685 199 289 1270 2.7
250^ 35/w 0.520 120 0.760 235 348 1500 3.0
300^ 35/w 0.570 120 0.810 282 404 1800 3.2
350 35/w 0.616 120 0.856 329 459 2100 3.4
400 35/w 0.659 120 0.899 376 514 2400 3.6
500 35/w 0.736 120 0.976 471 622 3000 3.9
600 58/w 0.813 135 1.083 565 753 3600 5.4
750 58/w 0.908 135 1.178 706 913 4500 5.9
1000^ 58/w 1.060 135 1.330 941 1178 6000 6.7

Data are approximate and subject to normal manufacturing tolerances.
^Non-stock item
*Minimum bending radius shown applies to permanent training. Larger radius should be used during cable pulling.
x Other colors available as non-stock items

KINGWIRE AL 2KV TYPE PV     Electrical Characteristics

Conductor Size DC Resistance
@ 25°C
AC Resistance
@ 75°C
Inductive Reactance+ Ampacity
@ 75°C*
Ampacity
@ 90°C*
AWG/Kcmil Ω/1000ft Ω/1000ft Ω/1000ft amps amps
4/0^ 0.084 0.100 0.041 180 205
250^ 0.071 0.086 0.041 205 230
300^ 0.059 0.071 0.041 230 260
350 0.051 0.062 0.040 250 280
400 0.044 0.054 0.040 270 305
500 0.035 0.044 0.039 310 350
600 0.029 0.036 0.039 340 385
750 0.024 0.031 0.038 385 435
1000^ 0.018 0.025 0.037 445 500

*Ampacities are based on NEC 2023 Table 310.16, Ampacities of Insulated Conductors in Raceway, Cable, or Earth (Directly Buried). Not more than 3 current-carrying conductors. Ambient temperature of 30°C.
+Inductive reactance based on NEC 2023, 3-Phase, 60 Hz, 75°C, 3-1/C in non-ferrous conduit.
^Non-stock item
x Other colors available as non-stock items

SPECIFICATIONS